Solar Panels That Plug into Your Wall

(nationalgeographic.com)

57 points | by speckx 2 hours ago

9 comments

  • ACCount39 1 hour ago
    Solar panels are getting cheap enough for grid hook-ups, installation and regulatory approval to become the bottlenecks.

    Plug-in solar is suboptimal in many ways, but it does sidestep a lot of those hurdles. Not too surprised to see it on the rise.

    Another thing that might be worth keeping in mind is that plug-in solar panels are often installed vertically - i.e. balcony solar. In which case the peak of the panel's generation is offset to the edge of the typical "duck curve". If it gets popular enough to affect the grid, it might get the solar-induced demand slump larger, but make the edges even sharper.

    Would that make grid scale battery storage with its instant response even more important?

    • Aurornis 44 minutes ago
      > it gets popular enough to affect the grid,

      The plug in solar systems are small and usually mounted in ways that don’t capture as much energy as the same panels mounted on a roof. These systems aren’t going to get popular enough to make a big difference in anything.

      I think it’s nice that they’re available for people to do some small scale offsets, but I think they’re more of a gateway to better solar installations. They also send people down the path of investigating battery storage add-ons, which might actually be a better long term solution for everyone.

      If we can get to a point where we can buy plug-in batteries that are subsidized by requiring coordination with the grid, the power companies could get distributed, controlled battery storage to work with their demand curves. This can already happen with the bigger permanent install batteries.

    • freediddy 1 hour ago
      Solar panel installation costs, at least in the US haven't dropped in 15 years. It's still $25-30k to install 4kW-6kW worth of solar panels.
      • mmh0000 11 minutes ago
        I'm in the SLC, Utah area, and just had 13.2 kW [30x440W Hyundai panels] (the most my city permits) of solar and 27 kWh [2x PowerWall3] of batteries installed for ~$35K by SmartWave Solar.

        I could have cut that cost by about 35% by installing the panels myself, but I don't have the time for it. So I paid for the labor.

      • rootusrootus 50 minutes ago
        Dominated by labor costs, right? It'll probably just keep going up at this point, even if the panel cost went to zero.
        • klardotsh 40 minutes ago
          Generally correct. Here in Washington I could get Signature Solar to ship me 31 excellent Canadian Solar bifacial panels on a pallet for $9200 plus tax and shipping (so add another grand or so). This would be 21kW of solar (plus a bit if bifacial gain kicks in), which is a ton - you could even do some winter work with that, if angled correctly.

          This setup would cost north of $50k (possibly north of $75k, depending) if installed by contractors. Labor costs are extremely high here, since COL is extremely high.

        • lostapathy 42 minutes ago
          A lot of the "labor" costs are just regulatory/permitting in disguise. An expedited approval regime with standards such that, permits-wise, installing solar panels was as easy as installing an EV charger would save a ton of money.

          Matt Ferrell just did a video on this recently https://www.youtube.com/watch?v=R3eEzdpi12I

        • cucumber3732842 30 minutes ago
          You're scooping up a lot of regulation and red tape in that "labor" bucket.
          • rootusrootus 24 minutes ago
            That's fair. I really meant 'installation' I suppose.
  • zanderwohl 1 hour ago
    This may be a stupid question, but I've always heard to never plug a generator into an outlet - what makes these safe enough that you can?
    • bluGill 45 minutes ago
      The biggest problem with plugging a generator into an outlet is you need a double ended cord. If you use everything correctly they work fine, but there are too many ways things can go wrong. The most obvious one is you plug everything in, start the generator, and the trip over the cord on you way back inside, thus sending the live male end flying toward you. Once in a while a kid will see these dual male plugs and plug them in - lots of ways things can go wrong here.

      There is also the problem of backfeeding, but this is more theoretical - even if you know to limit your power use, your neighbors won't and so your generator will trip its own breaker. Linemen are taught to either treat power lines like they are live, or to short them to ground - it can happen they don't do this and you kill a linemen, but still not as big a worry as it is made out.

      They make generator "inlets" that sidestep all these problems when used correctly. Most common I've seen is a block so you can't have the inlet and the main breaker both on at once.

    • bronco21016 1 hour ago
      The inverter box contains circuitry that cuts power output within some specified number of milliseconds if unplugged rendering the prongs "cold".
      • danans 1 hour ago
        It's not so much being unplugged as it is sensing whether the mains power is down. If it is, they stop backfeeding immediately, just like hardwired solar inverters do.

        If this weren't done, there would be risk of electricution to anyone working on wiring in the house or on the utility distribution network.

        • Kevin_Flynn 1 hour ago
          They have to sync up and feed power in phase with the grid when its up as well, in the case of net metering setups.
        • ortusdux 1 hour ago
          It's also important for the male plug prongs to not be live when unplugged.
        • bronco21016 1 hour ago
          I commented a little too quickly and left the nuance out. Your answer is much better!
      • zanderwohl 1 hour ago
        Thanks. I would have asked Claude or something but I know so little about this topic that I wouldn't have been skeptical enough of its answer.
    • gpm 1 hour ago
      Fancy power electronics in them that make sure they only send power to the outlet while the grid is energizing it too.
    • smallerize 1 hour ago
      In addition to the electronics that others mentioned, they also have limited amperage. That way even if you are pulling from your mains power and the solar at the same time, your circuit hardware shouldn't melt or catch fire.
    • Saris 57 minutes ago
      These sync with the grid and also have safety mechanisms to avoid backfeeding if the grid is down (or it's unplugged).
  • bigwheels 1 hour ago
  • pfdietz 46 minutes ago
    Perhaps also useful would be plug in batteries, especially if one has variable rates. Charge when cheap, discharge when expensive.

    One constraint on these I've read is that if you have sources and sinks on the same circuit, you might overload the line without tripping the breaker at the box. If I'm understanding this correctly this has caused them to limit the power of plug-in solar to a fraction of what a single circuit could potentially carry.

  • theoreticalmal 1 hour ago
    I hope the next step for this is plug-in battery storage. All the on-grid battery hybrid inverters I can find in the USA are either single leg 120V or 12kW for $5k. I just want like 3kW dual-leg with support for a dozen kWh of batteries
    • rootusrootus 31 minutes ago
      Yeah it seems like the inverter manufacturers don't see demand for that. I was thinking maybe the Victron Multiplus-II 2x120 could be paired for 240V output but I was wrong, that's only on grid power, it won't make 240V from battery.

      Obviously the inverters and pairing technology exist, but I don't know where to buy one retail.

    • bryanlarsen 35 minutes ago
      The Bluetti Apex 300 is an expandable 2.7kWh 3.8kW dual-leg battery + inverter + solar generator for ~$1000 (on sale).
    • Saris 42 minutes ago
      The EG4 12kPV does 8kw split phase output and is $3k, but haven't seen anything smaller than that yet.
  • michaelrpeskin 1 hour ago
    How do these work when plugged in to only one of the split phases on a US-style 120 system? Because I'm a nerd, I know which legs of the phase go to which outlet in my house, but I don't expect everyone to pay attention to that. I assume something has to take that into account somewhere.
    • ww520 24 minutes ago
      The electricity from the plug-in outlet is consumed by any devices connected on the same circuit first. Any excessive electricity is fed to the circuit breaker panel’s bar connecting all circuits on the same 120V split phase; the devices connected the the circuits on the same split phase can use the plug-in electricity next. Any excessive electricity is fed back out of the meter on the 120V split phase line on your main service connection, then to the electric company’s transformer at the street block. The transformer might feed it to your neighbors. In any case the transformer feed electricity to the other 120V split phase line back into your service connection, the meter, the panel, the other split phase bar, the circuits on it, and the outlets on them. The devices on the other split phase circuits technically are not using the plug-in power.

      Most modern meters will debit and credit the electricity going in and out on both split phase lines as net meter, so the electricity consumed in the other split phase is counted as consuming the plug-in power. However some old meters add the outgoing electricity up as consumption so you are paying for the electricity fed into the grid. Call your utility company to make sure.

      Also, unless you have a net metering agreement with your utility company, you won’t get paid for any excessive electricity fed back into the grid.

    • bluGill 37 minutes ago
      There is no problem and so nothing needs to account for it. A split phase is just a transformer with three windings, and one is connected to the other. We call one side (high voltage) the primary, and the other two secondary, but the transformer doesn't care at all, it can send power either way (there are limits but we are well under the maximum rating of the transformer so we can ignore them). If you only draw 240 volts then the two connected windings act as a single secondary, if you only draw 120 then one of the two secondaries provides power. Any other combination - the transformer doesn't care.
    • gizmo686 1 hour ago
      It backfeeds onto the grid and becomes the utility companies problem to deal with. This is similar to them dealing with a house that is an unbalanced consumer between the legs.
      • rootusrootus 42 minutes ago
        To my understanding, it is basically a non-issue at residential voltages. To be a problem it would require all the houses on a transformer (there are typically just a few for each transformer) to be unbalanced significantly in the same direction. That would be the end of it, too, because the 240V split only happens at the transformer.
  • tdhz77 1 hour ago
    If lightning strikes does the risk of fire increase with solar ac ?
  • sleepyguy 2 hours ago
  • 7e 1 hour ago
    This is fun, but utility-scale solar is far cheaper.
    • bruce511 1 hour ago
      It doesn't have to be cheaper than utility-scale. It only has to be cheaper than retail electricity.

      In other words, it can be useful even if it's not the most efficient way to do it. It only has to be more efficient than the status quo.

      I don't have thd capital to build utility-scale solar. I do have the capital to install residential solar. My electricity is now cheaper.

    • ww520 8 minutes ago
      Last I checked the biggest cost in the electric bill is transmission, by a wide margin. Home generated power however small helps everyone.
    • the__alchemist 1 hour ago
      There are advantages to distributed infrastructure as well! You mentioned one of the biggest disadvantages.

      I am thinking along the line of:

        - You can just do it / upgrade it etc
        - Robust against central failures for various reasons
        - Resistant to those in charge of centralized infrastructure abusing their monopoly
      • bluGill 33 minutes ago
        Utility solar is also distributed if there is enough of it installed to matter for discussion. A single installation is such a tiny share of the electric load that we can ignore if for all reasons you care about distributed. (or care about solar for that matter - it is a drop in the ocean for the environment)
    • cassianoleal 1 hour ago
      Utility-scale solar might be cheaper but doesn't make my house resilient to grid failures. It also only benefits me when the grid is upgraded enough that ... well, it benefits me.
      • gizmo686 1 hour ago
        Plug in solar doesn't make your house resilient to grid failures either. You would need an inverter that can generate an AC output without having an existing one to follow; a disconnect to isolate you from the grid during an outage, batteries to smooth the output, an electrician to install it, and an inspection to certify that it was all done correctly.

        If you are going through all of that, there is not much benefit to plug-in solar instead of traditional.

        • bryanlarsen 1 hour ago
          Most of the balcony solar packages already include what you need. They include a battery and on that battery is a receptacle that will supply power if there is no mains. The dogtail that you insert into your house outlet only supplies power if there is mains, but the receptacle on the battery supplies power regardless.

          So when the power goes out you unplug your fridge from the wall and plug it into the battery. In essence it operates like the standard camping battery/"solar generator", a la Jackery et al.

          • conductr 40 minutes ago
            To gp’s point, if you’re going through it all just implement it at your panel/subpanel. Mine does auto switch over to power the entire panel and I only know about it from an app notification. Then I can decide if and where I want to power down usage in the house to conserve battery.

            Having to plug in individual appliances seems to defeat the entire purpose. What happens if you’re away on holiday? Come home to a fridge full of trash? If power is back, do you even know how long the outage lasted? What about other devices that generally should have nonstop power or are typically hardwired? Sump pumps, HVAC equipment, water heaters, etc.

            • bryanlarsen 33 minutes ago
              Spending $3000 to add auto-switch to a $500 battery is not something most people are going to do.
      • gebruikersnaam 1 hour ago
        These panels do not work without the grid.
        • gpm 1 hour ago
          (And this is intentional to avoid electrocuting line workers who are working to fix the grid when it breaks)
          • SoftTalker 1 hour ago
            Line workers ground everything before they touch any conductors, except in some cases where they intentionally work "live."
            • adolph 48 minutes ago
              This is the truth. Aside from solar there are plenty of folks with backup generators that automatically come on whenever grid power fails. When maintenance crews came through my neighborhood to upgrade the old pole fixtures, they grounded out each block to keep any backfeed off what they were working on.
          • Analemma_ 1 hour ago
            No, it's more than that, it's not just a safety feature that you could disable: the plug-in panels need an existing waveform to synchronize to, if the grid is dead they can't produce an AC voltage signal on their own.
            • gizmo686 1 hour ago
              We know how to make inverters that can produce an AC voltage on their own. It is not particularly difficult or expensive. The reason why we do not put those inverters in plug-in solar units is entirely because we don't want them to have that ability.
              • bluGill 30 minutes ago
                Those are a different design inverter than cannot plug into a wall. It isn't hard to design either type, but they need different designs in some critical areas. (you can design one that will do both as well, but it would be more complex)
              • dylan604 1 hour ago
                Nobody claimed we didn't know how. You're misunderstanding the point of these panels.
    • bearjaws 1 hour ago
      Problem is for most of USA utility scale = utility profit for share holders.

      For example Duke is for profit here in Florida, and charges about 25% more per KWH than OUC that is a public utility.

      This leads to pricing where on one street your power bill is $250, but one street over its $200, often coming from the exact same power plant.

    • smallerize 1 hour ago
      I'm sure it's cheaper to somebody. But with home solar, I can actually cut my power bill by a noticeable fraction.
    • adrianN 1 hour ago
      It is easier to find a million people with a few hundred euros and a sunny balcony than finding one dude with a few hundred million euros and land on which building a solar farm is permitted.
    • freediddy 1 hour ago
      It's not and it will NEVER be.

      Utility companies are not incentivized to lower prices because it means less money for them. Do you remember when power companies told people to conserve power and then people successfully did this? And then they raised rates because they weren't making enough money? This happens in California ALL THE TIME. I've lived here 30 years in Silicon Valley and it's the biggest scam that no one talks about. It happens with electricity and water. With water its even more egregious because they told us to conserve water because of the "drought" but once the drought was over, they raised rates because people weren't using enough water. My connection fee to water is over $100/month without spending a drop of water. That's why I stopped conserving water and water my lawn every single day because it turns out that my water costs are only about 1/3 of the actual water bill costs so fuck it!

      It's the same playbook over and over again, there's no incentive to lower rates at all because it's an easy way to make money over an entire population of tens of millions of people.

      Now PG&E is fighting to charge solar panel owners $100+/month just for the privilege of being connected to the grid. That would make having solar panels even more expensive than not having solar panels which is utter hypocrisy but no one seems to care or point this out. It's a complete and utter scam.

      EDIT: I forgot to mention last year the rates were $0.37-0.45 per kWh, until this year when they implemented a base fee of $25/month, so they lowered it to $0.33-0.45/kWh. Rates in Nevada are 1/4 of that.

      2015: $0.17-0.33 per kWh

      2020: $0.24-0.38 per kWh

      so prices have more than doubled in 10 years. Fucking criminals.

      • Kevin_Flynn 1 hour ago
        I live in Florida, and I'm building a water battery, so I can freeze it at night when electricity rates are cheap, and use it to cool the house during the day.

        The day after the system goes live, they'll probably announce flat rates for any time of day, just to f' with me. :(

    • fred_is_fred 48 minutes ago
      Where I live we have Time of Day electricity pricing where the prices jump 2-3x during high demand. Panels conveniently produce the most power around this time, so this can save people money.
    • delichon 1 hour ago
      We should build now in anticipation of drone warfare. Utility-scale solar is easier to take out. Same as natural disasters.

      The more stable you think the future will be, the more you want to capture the efficiency of central power.

      • bronco21016 1 hour ago
        By that logic literally everything should be distributed. That's going to be a big undertaking to re-architect our entire civilian infrastructure against that.

        I'm not saying you're necessarily wrong, I just don't see society taking that measure until it's either 1) cheaper, or 2) the threat moves from being just a threat to reality.

        • delichon 1 hour ago
          > 2) the threat moves from being just a threat to reality.

          Completely agree. But I'm already there. Large scale economic disruption has just started. For that to remain peaceful over the next few decades would be a miracle. So we should plan for disruption, for which energy decentralization is a keystone, and the technology to make it practical is here.

          California has a 600 MW Virtual Power Plant composed of Tesla Powerwall batteries in 85k homes. Central control of distributed generation removes a lot of inefficiencies. Household excess is available to the whole system.

          • freediddy 1 hour ago
            Has no one been paying attention to how Ukraine/Russia and now Iran has been targeting civilian infrastructure? All of Spain's electricity was down last year from a cyberattack. This is completely a new line of threat that we need to address.